<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-10 03-43-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 60 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 68 kHz 13661 13,1908
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,5 dBr 5,19 dBr 5,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 68 kHz MIN: 12 kHz % above 76 kHz: 13,1908 Acquired: 2025/05/10 3.42.46 Total samples: 13661 Equivalent time: 0:11:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,5 dBr MIN: 4,5 dBr AVE: 5,19 dBr % above 12,2 dBr: 0,0 Last value: 5,0 dBr (2025/05/10 3.42.46) 03.28 03.30 03.32 03.34 03.36 03.38 03.40 03.42 0 2 4 6 Pm [dBr]